Unpacking & Setup
The TankerTherm 123 ships partially crated to protect the distribution manifold plumbing. Follow these steps carefully to avoid damage during unpacking.
Before you unpack
|
Verify the shipment
Two items are loose-packed inside the cabinet. Confirm both are present before proceeding:
The red expansion vent hose is factory-installed at the storage tank end. The free (drum) end is fitted with the drum vent hose-barb described below — connect this to your supply drum during installation. |
Removing the crating
|
Use care when removing crating
Blocking strips are wedged behind the manifold. Sliding them out carelessly can damage distribution plumbing. |
-
Remove the crating using special care when sliding out blocking strips.
-
To remove the cabinet door:
-
Remove the two bolts that secure the door near the bottom on either side.
-
Pull the door out at the bottom.
-
Gently slide the door down and away from the top lid.
-
Installing loose-packed components
OVERFLOW and REFILL IN hose barbs for the supply-drum hoses are at the top of the rear panel
REFILL IN through the suction filter, and the red vent hose runs from OVERFLOW back to the drum. Illustration: the unit is a photograph, the surroundings are computer-generated to show a typical installation.Install the two loose-packed items (suction filter, suction tube/hose assembly) into the bulkhead fittings.
|
Prevent bulkhead rotation
Before tightening any fitting, secure the bulkhead fitting from rotation with a crescent wrench. Rotating a bulkhead can damage internal connections and void your warranty. |
Drum vent hose-barb fitting
The fitting at the drum end of the factory-installed red expansion vent hose connects the storage tank’s atmospheric vent to your supply drum so that any expansion overflow drains back into the drum.
The drum vent 5/8″ hose-barb fitting is designed for re-use on each
successive drum. When swapping drums:
-
Screw the fitting into the
3/4″ NPTplug fitting hand tight -
Do not use thread sealant
-
Do not use a hose clamp